『Klikkige siia, et laadida alla toote PDF: Plahvatuskindel kliimaseade BKFR』
Tehnilised parameetrid
Mudel | BKFR-25 | BKFR-35 | BKFR-50 | BKFR-72 | BKFR-120 | |
---|---|---|---|---|---|---|
Nimipinge/-sagedus | 220V/380V/50Hz | 380V/50Hz | ||||
Rated cooling capacity (W) | 2600 | 3500 | 5000 | 7260 | 12000 | |
Rated heat (W) | 2880 | 3900 | 5700 | 8100 | 12500 | |
Input power (P number) | 1P | 1.5P | 2P | 3P | 5P | |
Külmutusseadme sisendvõimsus/vool (W/A) | 742/3.3 | 1015/4.6 | 1432/6.5 | 2200/10 | 3850/7.5 | |
Kütte sisendvõimsus/vool (W/A) | 798/3.6 | 1190/5.4 | 1690/7.6 | 2600/11.8 | 3800/7.5 | |
Applicable area (m ²) | 10~12 | 13~16 | 22~27 | 27~34 | 50~80 | |
Noise (dB) | indoor | 34.8/38.8 | 36.8/40.8 | 40/45 | 48 | 52 |
outdoor | 49 | 50 | 53 | 56 | 60 | |
Overall dimension (mm) | Indoor unit | 265x790x170 | 275x845x180 | 298x940x200 | 326x1178x253 | 581x1780x395 |
Outdoor unit | 540x848x320 | 596x899x378 | 700x955x396 | 790x980x440 | 1032x1250x412 | |
Control box | 300x500x190 | 300x500x190 | 300x500x190 | 300x500x190 | 250x380x165 | |
Kaal (kg) | Indoor unit | 12 | 10 | 13 | 18 | 63 |
Outdoor unit | 11 | 41 | 51 | 68 | 112 | |
Control box | 10 | 7 | ||||
Length of connecting pipe | 4 | |||||
Plahvatuskindel märk | Ex db eb ib mb IIB T4 Gb Ex db eb ib mb IIC T4 Gb |
|||||
Maximum outer diameter of incoming cable | Φ10~Φ14mm | Φ15~Φ23mm |
Split explosion-proof air conditioning treatment
1. Wall mounted explosion-proof air conditioners and floor mounted explosion-proof air conditioners are mainly used for explosion-proof treatment of outdoor units and indoor units on the basis of ordinary air conditioners, as follows:
(1) Outdoor unit: it is mainly used for internal electrical control part, compressor, outdoor fan, protection system, heat dissipation system and refrigeration system explosion proof treatment shall be carried out in a unified way. Its overall dimensions are the same as those of the external units of ordinary hanging air conditioners, and its installation method is also the same as that of the external units of ordinary hanging air conditioners.
(2) Indoor unit: it mainly adopts special process treatment methods and manufacturing methods to decompose the internal electrical control part, and then re conduct explosion-proof design, manufacturing and processing to form an independent explosion proof control box, with manual control function, its hanging external dimension is the same as that of the ordinary hanging internal machine, and its installation method is also the same. But the explosion-proof indoor unit is increased a hanging plahvatuskindel juhtimiskast is provided, and its dimensions are shown in the figure below.
2. A variety of explosion-proof forms are used outside the explosion-proof indoor unit and outdoor unit, and the iseenesest ohutu explosion-proof circuit is used for the weak current control part.
Toote omadused
1. Explosion proof air conditioner is made of explosion-proof treatment on the basis of ordinary air conditioner, with reliable explosion-proof performance and no impact on the performance of the original air conditioner.
2. Explosion proof air conditioners can be divided into: split wall mounted type and floor mounted type according to structure, and can be divided into: single cold type and cold and warm type according to function.
3. The connection of plahvatuskindel kliimaseade pipeline is consistent with that of ordinary air conditioner. The electrical connection must be in accordance with the requirements of explosion-proof electrical installation process. The power supply must be introduced into the explosion-proof control box first, and then divided from the explosion-proof control box.
Do not introduce the indoor unit and outdoor unit.
4. The explosion-proof control box is equipped with a power switch.
5. Terastoru või kaablijuhtmestik on vastuvõetav.
Kohaldatav ulatus
1. Seda kohaldatakse 1. ja 2. tsooni kohtade suhtes. plahvatusohtlik gaasikeskkond;
2. Suitable for IIA, IIB and IIC explosive gas environment;
3. Applicable to T1~T6 temperatuur rühmad;
4. It is applicable to dangerous environments such as oil exploitation, oil refining, chemical industry, gas station, offshore oil platforms, oil tankers and metal processing;
5. It is used for temperature regulation in workshops, control rooms, laboratories and other fields.