A key aspect to consider for metal materials in explosion-proof electrical equipment is their propensity to ignite explosive gas-air mixtures through mechanical sparks. Research has indicated that the composition of these metals plays a substantial role in their ignition potential. To prevent the occurrence of mechanical spark ignition in metal enclosures, specific elemental limitations are mandated. The standards for explosive environments – General Equipment Requirements – specify the following:
I klass
In producing RPL level MA or Mb explosion-proof electrical equipment, the composition of aluminum, magnesium, titanium, and zirconium in the enclosure materials must not exceed 15% by mass, and the combined mass percentage of titanium, magnesium, and zirconium must not surpass 7.5%.
II klass
II klassi plahvatuskindlate elektriseadmete tootmisel varieerub kriitiliste elementide kogumassiprotsent korpuse materjalides sõltuvalt kaitsetasemest: EPLGa seadmete puhul ei tohi alumiiniumi, magneesiumi, titaani ja tsirkooniumi kogusisaldus ületada 10%, kusjuures magneesiumi, titaani ja tsirkooniumi kogusisaldus ei tohi ületada 7,5%; EPLGb seadmete puhul ei tohi magneesiumi ja titaani kogusisaldus ületada 7,5%; EPLGc seadmete puhul ei ole lisaks EPLGb standarditele vastavatele ventilaatoritele, ventilaatorikattele ja ventilatsiooniavade kaitsekestadele täiendavaid erinõudeid.
III klass
III klassi plahvatuskindlate elektriseadmete valmistamisel varieerub vastavalt kaitsetasemele ka korpusmaterjalide asjakohaste elementide nõutav kogumassiprotsent: EPLDa seadmete puhul ei tohi magneesiumi ja titaani sisaldus ületada 7,5%; EPLDb seadmete puhul kehtib sama piirang; EPLDc seadmete puhul ei ole peale ventilaatorite, ventilaatorite katete ja ventilatsiooniavade piirdetarindite, mis vastavad EPLDb kriteeriumidele, mingeid täiendavaid erinõudeid.