『Clicca qui per scaricare il PDF del prodotto: Ventilatore a flusso assiale antideflagrante BT35』
Parametro tecnico
Segnale antideflagrante | Protection grade | Rated frequency (S) | Diametro esterno del cavo | Filettatura di ingresso |
---|---|---|---|---|
Ex db IIC T4 Gb Ex tb IIIC T135℃ Db | IP54 | 50 | φ10-φ14 | G3/4 or pressure plate |
Modello e specifiche | Impeller diameter (mm) | Tensione nominale (V) | Rated speed (r/min) | Impeller angle | Air volume (m3 /h) | Total pressure (Pa) | Installed power (Kw) |
---|---|---|---|---|---|---|---|
BT35-2# | 200 | 380/220V | 2800 | 43° | 1230 | 112 | 0.09 |
1450 | 618 | 64 | 0.06 | ||||
BT35-2.8# | 280 | 2800 | 35° | 2921 | 190 | 0.25 | |
1450 | 1510 | 105 | 0.18 | ||||
BT35-3.15# | 315 | 2800 | 3074 | 218 | 0.37 | ||
1450 | 1998 | 141 | 0.25 | ||||
BT35-3.55# | 355 | 2800 | 3367 | 246 | 0.37 | ||
1450 | 2188 | 160 | 0.25 | ||||
BT35-4# | 400 | 3560 | 260 | 0.37 | |||
BT35-4.5# | 450 | 38° | 3450 | 142 | |||
42° | 4644 | 150 | 0.55 | ||||
BT35-5# | 550 | 380 | 38° | 7655 | 116 | ||
43° | 8316 | 123 | 0.75 | ||||
BT35-5.6# | 560 | 9581 | 173 | ||||
48° | 11682 | 186 | 1.1 | ||||
BT35-6.3# | 630 | 41° | 10736 | 154 | |||
45.2° | 14454 | 160 | 1.5 | ||||
BT35-7.1# | 710 | 40° | 13400 | 178 | 1.1 | ||
43.5° | 16160 | 189 | 1.5 | ||||
960 | 46° | 14498 | 123 | 1.1 | |||
BT35-8# | 800 | 44° | 31325 | 180 | 2.2 | ||
37073 | 248 | 4.0 | |||||
BT35-9# | 900 | 46° | 35227 | 200 | 3.0 | ||
39800 | 230 | 4.0 | |||||
BT35-10# | 1000 | 48300 | 247 | 5.5 | |||
54300 | 268 | 7.5 | |||||
BT35-11.2# | 1120 | 42° | 56460 | 353 | |||
46° | 67892 | 415 | 11 |
caratteristiche del prodotto
1. This series of ventilators are designed based on the three dimensional flow theory of turbomachinery, and the test data are carefully designed to ensure the excellent aerodynamic performance of the ventilator, featuring low noise, high efficiency, low vibration, low energy consumption, eccetera;
2. The ventilator is composed of explosion-proof motor, impeller, air duct, protective cover, eccetera;
3. For ventilation and exhaust, it can also be installed in series in a short exhaust pipe to increase the pressure of the pipe;
4. Default cable wiring. If steel pipe wiring is required, it should be noted when ordering.
Machine No | L(mm) | D1(mm) | D2(mm) |
---|---|---|---|
2# | 280 | 210 | 260 |
2.8# | 290 | 340 | |
3.15# | 325 | 375 | |
3.55# | 320 | 365 | 415 |
4# | 370 | 410 | 460 |
4.5# | 460 | 510 | |
5# | 510 | 550 | |
5.6# | 450 | 570 | 620 |
6.3# | 640 | 690 | |
7.1# | 720 | 770 | |
8# | 630 | 810 | 860 |
9# | 910 | 960 | |
10# | 1010 | 1060 | |
11.2# | 1130 | 1180 |
Ambito applicabile
1. È applicabile ai luoghi in Zona 1 e Zona 2 Di esplosivo ambiente gassoso;
2. È applicabile ai luoghi in Zona 21 E 22 Di polvere combustibile ambiente;
3. Adatto per IIA, Ambiente con gas esplosivo IIB e IIC;
4. Applicable to T1-T4 temperatura group;
5. It is widely used in oil refining, chimico, tessile, gas station and other dangerous environments, piattaforme petrolifere offshore, petroliere e altri luoghi;
6. Indoor and outdoor.