25 Year Industrial Explosion-Proof Manufacturer

Explosion-ProofAnalyzerShelterBPW|ProductCenter

Explosion-Proof Electrical Equipment/

Explosion-Proof Analyzer Shelter BPW

Type:Flameproof Analyzer Shelter For Hazardous Locations

Color:Steel Natural Finish

Ex Mark:Ex de ib [ib] P II BT4 Gb, Ex de ib [ib] P IIC T4 Gb,DIP A20 TA T4

IP Rating:IP66

Model Number:BPW

Warranty(Year):3-Year

Place of Origin:Zhejiang, China

Product Weight(kg):1500

  • Product Details
  • About Us
  • FAQ
  • Shipping And Payment

Model Meaning

explosion-proof analyzer shelter bpw model meaning

Implementation Standard

GB/T3836.1、GB/T3836.2、GB/T3836.3、GB/T3836.4、GB/T3836.5、GB/T3836.17、IEC 60079-0、IEC 60079-1、IEC 60079-2、IEC 60079-7、IEC 60079-11、IEC 60079-13、EN 60079-11、EN 60079-13。

Technical Parameter

explosion-proof analyzer shelter bpw-7
1. Explosion-proof marking: Ex db eb ib mb pz IIC T4 Gc

2. Power supply: 220VAC ±10%, 50Hz or AC380V ±10%, 50Hz or as per user requirements;

3. Protection Rating: IP65 Audible and Visual Alarm: Activates when hazardous gas concentration exceeds threshold (25% LEL) inside the enclosure Audible and Visual Alarm: Activates when toxic gas concentration exceeds threshold (12.5 ppm) inside the enclosure Normal Indoor Pressure Range: 30–100 Pa Enclosure Material: Carbon steel, stainless steel Dimensions: Customized per user requirements

Implementation StandardsDegree of protection
Explosion-Proof MarkingIP66
Power SupplyEx de ib [ib] P II BT4 Gb, Ex de ib [ib] P II CT4 Gb, DIP A20 TA T4
Protection Rating220V AC ± 10%, 50Hz or AC 380V ± 10%, 50Hz or according to user requirements
Sound and light alarm when the concentration of hazardous gases in the cabin exceeds the limit (25% LEL)
Sound and light alarm when the concentration of toxic gas in the cabin exceeds the limit (12.5ppm)
Normal indoor pressure value30-100pa
Appearance materialcarbon steel, stainless steel
External dimensionscustomized according to user requirements

Product Features

1. The positive pressure explosion-proof analysis cabin integrates the assembly, installation, and application of industrial online instruments, finding widespread use in oilfields, refineries, and chemical plants.

2. This series provides explosion-proof solutions for centralized on-site control, command coordination, process analysis, and instrument monitoring, offering unmatched advantages over other explosion-proof structures.

3. The system comprises the main chamber structure, positive pressure control system, positive pressure ventilation system, pressure monitoring system, combustible gas detection system, toxic gas detection system, high-temperature alarm system, smoke alarm system, audible-visual alarm interlock system, lighting system, temperature/humidity regulation system, universal power supply system, and user electrical system;

4. An explosion-proof air conditioner is installed indoors to regulate temperature, providing constant temperature and humidity control;

5. The power distribution system employs a pipeline configuration with explosion-proof control boxes;

6. The lighting system utilizes explosion-proof ceiling lights and explosion-proof emergency lights, with standard illumination provided by tubular fluorescent lamps;

7. The chamber incorporates ventilation, air exchange, and filtration devices. The intake duct of the chamber must be located in a non-hazardous area;

8. Features double-sealed doors with glass viewing windows and escape doors, providing dustproof and waterproof capabilities;

9. Fully enclosed system with anti-static, spark-proof, environmentally non-polluting, corrosion-resistant, and anti-interference functions;

10. Utilizes PLC integrated control technology for stable and reliable system operation, with overall grounding and ground resistance <4Ω.

explosion-proof analyzer shelter bpw-8
explosion-proof analyzer shelter bpw-9
explosion-proof analyzer shelter bpw-10
explosion-proof analyzer shelter bpw-11
explosion-proof analyzer shelter bpw-12
explosion-proof analyzer shelter bpw-15
explosion-proof analyzer shelter bpw-16

Typical Solution Diagram

explosion-proof analyzer shelter bpw typical solution diagram

System Components

DiagramNameSpecification ModelKey ParametersRemarks
system components - process control chromatographProcess Control ChromatographABB PGC50001. Explosion-proof rating: Class 1, Div 1, Gr. B.C. DT4
2. Multiple models of PGC5000 Smart Ovens™
(column ovens) capable of performing any gas or liquid phase analysis project
3. True color 26.42 cm (10.4-inch) SVGA LCD display
4. Graphical human-machine interface (HMI) for viewing real-time chromatograms
Configure according to design requirements
system components - continuous analyzer-1Continuous AnalyzerABB EL30601. Explosion-proof marking: II 2G; Ex de IIC T4
2. Touchscreen display ensures safe operation.
3. Flameproof instruments specifically designed for hazardous areas
4. Compact structure for easy integration
5. Analyzer consists of a control unit and analysis modules 6. Analysis modules include infrared photometer Uras26, paramagnetic oxygen analyzer Magnos206, thermal conductivity analyzer Caldos27, Caldos25
Configure according to design requirements
system components - continuous analyzer-2Continuous AnalyzerABB AO20001. Explosion-proof rating: Class 1, Division 2, Groups A, B, C, DT4
2. One central unit and up to four analyzer modules
3. Analyzer modules include photometers, in-situ laser analyzers,
oxygen analyzers, thermal conductivity analyzers, infrared analyzers,
ultraviolet analyzers, and FID analyzers
Configure according to design requirements
system components - pre-treatment systemPre-treatment SystemRequired Configuration1. The sample pretreatment system comprises sampling probes, pre-treatment stages, pretreatment units, and sample transfer lines.
2. It performs functions including pressure reduction, filtration, cooling, temperature and flow control, and flow switching.
3. Instrumentation and piping components are sourced from internationally renowned brands such as Swagelok, Parker, Fitok, and SMC.
system components - gas detectorGas DetectorConfigure as per design requirements1. Explosion-proof marking: Ex db IIC T6 Gb
2. Detects toxic, hazardous, flammable, and explosive gas concentrations
3. Operating voltage: DC 12–30V
Signal output: 4–20 mA + alarm contact
Configure according to design requirements
system components - plcPLCSIEMENS SIMATIC1. Control the safety detection system for the analytical cabin
2. Control the switching of multi-channel pretreatment flow paths
system components - explosion-proof exhaust fanExplosion-Proof Exhaust FanConfigure as per design requirements1. Explosion-proof marking: Ex db IIC T4 Gb
2. Voltage rating: AC 220V 50Hz
3. Airflow: 24m³/min
system components - audible and visual alarmAudible and Visual AlarmBBJ-2201. Explosion-proof marking: Ex db IIC T4 Gb
2. Rated voltage: AC 220V
3. Integrated sound and light design
system components - explosion-proof distribution boxExplosion-Proof Distribution BoxConfigure as per design requirements1. Explosion-proof marking: Ex db IIC T6 Gb
2. Voltage rating: AC 220V/380V 50Hz
3. Rated current: 63A
system components - explosion-proof junction boxExplosion-Proof Junction BoxConfigure as per design requirements1. Explosion-proof marking: Ex db IIC T6 Gb
2. Voltage rating: AC 220V/380V 50Hz
3. Rated current: 63A
system components - explosion-proof control boxExplosion-Proof Control BoxConfigure as per design requirements1. Explosion-proof marking: Ex db eb IIC T6 Gb
2. Voltage rating: AC 220V/380V 50Hz
3. Rated current: 16A
system components - explosion-proof fluorescent lampExplosion-Proof Fluorescent LampBPY961. Explosion-proof marking: Ex db IIC T6 Gb
2. Voltage rating: AC 220V/380V 50Hz
3. Rated power: 30W
system components - explosion-proof plug-in deviceExplosion-Proof Plug-in DeviceAC-16/2201. Explosion-proof marking: Ex db eb IIC T6 Gb
2. Voltage rating: AC 220V 50Hz
3. Rated current: 16A
system components - explosion-proof switchExplosion-Proof SwitchBZM8030-10/2201. Explosion-proof marking: Ex db eb IIC T6 Gb
2. Voltage rating: AC 220V 50Hz
3. Rated current: 10A
system components - explosion-proof air conditionerExplosion-Proof Air ConditionerBKFR1. Explosion-proof marking: Ex db eb ib mb IIC T4 Gb
2. Voltage rating: AC 220/380V 50Hz
3. Rated cooling capacity: As required
4. Rated heating capacity: As required
system components - gas sampling pumpGas Sampling Pumpbuhler1. Explosion-proof marking: Ex II2 G E Ex c IIC T1-T4
2. Rated voltage: AC 230V
3. Rated flow rate: 400L/H

Applicable Scope

1. Suitable for Zone 2 explosive gas environments;

2. Temperature classes T1-T4;

3. Suitable for flammable and explosive gas environments in petroleum extraction, refining, chemical processing, military applications, offshore oil platforms, oil tankers, and similar settings.

company profile-1company-profile-2
sample room our certificate exhibition

Q: Are you factory or trading company?
A: We are a factory and provide OEM services. Our main products are explosion-proof lightings, explosion-proof distribution box, explosion-proof cable gland, explosion-proof fans, explosion-proof junction box and anti-corrosion & dustproof & waterproof lights.

Q: What certificates do you have?
A: We have passed ATEX, IECEx, and with a lot of National Patents.

Q: What place are your products used in?
A: They are widely used in petroleum chemical, aerospace, coal electrical power, railway, metallurgy, shipbuilding, medicine, marine, wine-making, fire fighting, municipal and other industries.

Q: Can I have a sample order?
A: Yes, we welcome sample orders to test and check quality. Mixed samples are acceptable.

Q: Can you accept customized?
A: Yes. Please inform us and confirm the design firstly based on our sample.

shipping and payment

Next:

Get a Quote ?