『Kliknite ovdje za preuzimanje proizvoda u PDF-u: Explosion Proof Light BED61』
Technical Parameter
Model and specification | Znak otporan na eksploziju | Light source | Lamp type | Power (W) | Luminous flux (Lm) | Color temperature (k) | Weight (kg) |
---|---|---|---|---|---|---|---|
BED61-□ | Ex db IIC T6 Gb Ex tb IIIC T80°C Db | LED | I | 10~30 | 1200~3600 | 3000~5700 | 2.4 |
II | 40~60 | 4800~7200 | 3.5 | ||||
III | 70~100 | 8400~12000 | 5.4 | ||||
IV | 120~150 | 14400~18000 | 6 |
Rated voltage/frequency | Inlet thread | Cable outer diameter | Stepen zaštite | Anti corrosion grade |
---|---|---|---|---|
220V/50Hz | G3/4 | Φ10~Φ14mm | IP66 | WF2 |
Emergency starting time (S) | Charging time (h) | Emergency power (within 100W) | Emergency power (W) | Emergency lighting time (min) |
---|---|---|---|---|
≤0.3 | 24 | ≤20W | 20W~50W optional | ≥60min、≥90min optional |
Karakteristike proizvoda
1. The radiator design is made of special cast aluminum alloy die-casting, with high-pressure electrostatic spraying on the surface
2. High anti-corrosion stainless steel exposed fasteners;
3. The sealing explosion-proof joint surface is a pure explosion-proof structure, with more reliable explosion-proof performance;
4. Multi point luminescence, high light utilization rate, uniform illumination without glare;
5. Constant current power supply with wide voltage input and constant current output, with protection functions such as shunt, anti surge, overcurrent, open circuit, open circuit, high temperaturu, and anti electromagnetic interference;
6. Microwave induction dimming system, energy-saving and environmentally friendly;
7. Power factor cos φ≥ 0.95;
8. Combination emergency devices can be equipped according to usage requirements. When the power supply is cut off, it can automatically switch to the emergency lighting state;
9. Steel pipe or cable wiring.
Installation Dimensions
Serial No | Specification and model | Type of lamp housing | Power range (W) | Φ(mm) | h(mm) | A(mm) |
---|---|---|---|---|---|---|
1 | BED61-30W | I | 10-30 | 181 | 195 | 80 |
2 | BED61-60W | II | 40-60 | 225 | 216 | 95 |
3 | BED61-100W | III | 70-100 | 254 | 230 | 95 |
4 | BED61-150W | IV | 120-150 | 291 | 235 | 120 |
Primjenjiv opseg
1. Primjenjivo je na mjesta u Zoni 1 i Zona 2 of eksplozivno gasno okruženje;
2. Primjenjivo je na mjesta u Zoni 21 i 22 of zapaljive prašine okruženje;
3. Pogodno za IIA, IIB i IIC eksplozivno gasno okruženje;
4. Applicable to T1~T6 temperature groups;
5. It is applicable to energy-saving transformation projects and places where maintenance and replacement are difficult;
6. It is widely used for lighting in oil exploitation, preradu nafte, hemijska industrija, benzinska pumpa, textile, food processing, morske naftne platforme, oil tankers and other places.