『Cliquez ici pour télécharger le PDF du produit: Démarreur électromagnétique antidéflagrant BQC』
Paramètre technique
Signe antidéflagrant | Tension nominale | Protection level | Corrosion protection level |
---|---|---|---|
Ex db eb IIB T4 Gb Ex db eb IIC T4 Gb Ex tb IIC T130℃ Db | 380V | IP66 | WF1*WF2 |
Model | Courant nominal | Thermal relay constant current regulation range | Control the maximum power of the motor | Diamètre extérieur du câble | Filetage d'entrée |
---|---|---|---|---|---|
BQC-9/□ | 9UN | 6.8~11A | 4kW | φ10~φ14mm | G3/4 |
BQC-12/□ | 12UN | 6.8~11A | 5.5kW | ||
BQC-18/□ | 18UN | 10~16A | 7.5kW | ||
BQC-22/□ | 22UN | 14~22A | 11kW | ||
BQC-25/□ | 25UN | 20~32A | 11kW | φ12~φ17mm | G1 |
BQC-32/□ | 32UN | 20~32A | 15kW | ||
BQC-40/□ | 40UN | 28~45A | 18.5kW | φ15~φ23mm | G1 1/4 |
BQC-50/□ | 50UN | 40~63A | 22kW | φ18~φ33mm | G1 1/2 |
BQC-65/□ | 65UN | 40~63A | 30kW | ||
BQC-80/□ | 80UN | 63~80A | 37kW | ||
BQC-100/□ | 100UN | 80~100A | 45kW | ||
BQC-9/□/N | 9UN | 6.3~10A | 4kW | φ10~φ14mm | G3/4 |
BQC-12/□/N | 12UN | 8~12.5A | 5.5kW | ||
BQC-18/□/N | 18UN | 10~16A | 7.5kW | ||
BQC-22/□/N | 22UN | 12.5~20A | 11kW | ||
BQC-25/□/N | 25UN | 20~32A | 11kW | φ12~φ17mm | G1 |
BQC-32/□/N | 32UN | 20~32A | 15kW | ||
BQC-40/□/N | 40UN | 37~50A | 18.5kW | φ15~φ23mm | G1 1/4 |
BQC-50/□/N | 50UN | 37~50A | 22kW | φ18~φ33mm | G1 1/2 |
BQC-65/□/N | 65UN | 48~65A | 30kW | ||
BQC-80/□/N | 80UN | 63~80A | 37kW | ||
BQC-100/□/N | 100UN | 80~100A | 45kW |
Electrical Schematic Diagram
caractéristiques du produit
1. Aluminum alloy die-casting shell, après grenaillage à grande vitesse, the surface is coated with high-voltage electrostatic spraying, which is corrosion resistant and anti-aging;
2. Stainless steel exposed fasteners with high anti-corrosion performance;
3. Equipped with AC contactors, thermal relays, and self resetting universal transfer switches, and equipped with a high breaking small circuit breaker when equipped with a main switch;
4. It can control the direct start and stop of AC 50Hz, 380V three-phase asynchronous motors, and has overload, phase failure, and voltage loss protection;
5. It can be equipped with remote control;
6. Des tuyaux ou des câbles en acier sont acceptables..
Standard IIB
Standard IIC
Reversible IIB
Reversible IIC
Portée applicable
1. Suitable for explosif gas environments in Zone 1 et zone 2 locations;
2. Suitable for places in Zone 21 et zone 22 with poussière combustible environments;
3. Convient pour IIA, IIB, and IIC explosive gas environments;
4. Suitable for température groups T1 to T6;
5. It is suitable for infrequent starting and stopping of three-phase asynchronous motors in dangerous environments such as oil exploitation, raffinage de pétrole, industrie chimique, gas stations, offshore oil platform, pétroliers, traitement des métaux, etc..