『Smelltu hér til að hlaða niður vörunni PDF: Portable Explosion Proof Axial Flow Fan BT35』
Tæknileg færibreyta
Sprengingarvarið merki | Protection grade | Rated frequency (S) | Ytra þvermál kapals | Inntaksþráður |
---|---|---|---|---|
Ex db IIC T4 Gb Ex tb IIIC T135℃ Db | IP54 | 50 | φ10-φ14 | G3/4 or pressure plate |
Gerð og forskrift | Impeller diameter (mm) | Málspenna (V) | Rated speed (r/min) | Impeller angle | Air volume (m3 /h) | Total pressure (Pa) | Installed power (Kw) |
---|---|---|---|---|---|---|---|
BT35-2# | 200 | 380/220V | 2800 | 43° | 1230 | 112 | 0.09 |
1450 | 618 | 64 | 0.06 | ||||
BT35-2.8# | 280 | 2800 | 35° | 2921 | 190 | 0.25 | |
1450 | 1510 | 105 | 0.18 | ||||
BT35-3.15# | 315 | 2800 | 3074 | 218 | 0.37 | ||
1450 | 1998 | 141 | 0.25 | ||||
BT35-3.55# | 355 | 2800 | 3367 | 246 | 0.37 | ||
1450 | 2188 | 160 | 0.25 | ||||
BT35-4# | 400 | 3560 | 260 | 0.37 | |||
BT35-4.5# | 450 | 38° | 3450 | 142 | |||
42° | 4644 | 150 | 0.55 | ||||
BT35-5# | 550 | 380 | 38° | 7655 | 116 | ||
43° | 8316 | 123 | 0.75 | ||||
BT35-5.6# | 560 | 9581 | 173 | ||||
48° | 11682 | 186 | 1.1 | ||||
BT35-6.3# | 630 | 41° | 10736 | 154 | |||
45.2° | 14454 | 160 | 1.5 | ||||
BT35-7.1# | 710 | 40° | 13400 | 178 | 1.1 | ||
43.5° | 16160 | 189 | 1.5 | ||||
960 | 46° | 14498 | 123 | 1.1 | |||
BT35-8# | 800 | 44° | 31325 | 180 | 2.2 | ||
37073 | 248 | 4.0 | |||||
BT35-9# | 900 | 46° | 35227 | 200 | 3.0 | ||
39800 | 230 | 4.0 | |||||
BT35-10# | 1000 | 48300 | 247 | 5.5 | |||
54300 | 268 | 7.5 | |||||
BT35-11.2# | 1120 | 42° | 56460 | 353 | |||
46° | 67892 | 415 | 11 |
Eiginleikar Vöru
1. This series of ventilators are designed based on the three dimensional flow theory of turbomachinery, and the test data are carefully designed to ensure the excellent aerodynamic performance of the ventilator, featuring low noise, high efficiency, low vibration, low energy consumption, o.s.frv;
2. The ventilator is composed of explosion-proof motor, impeller, air duct, protective cover, o.s.frv;
3. For ventilation and exhaust, it can also be installed in series in a short exhaust pipe to increase the pressure of the pipe;
4. Default cable wiring. If steel pipe wiring is required, it should be noted when ordering.
Machine No | L(mm) | D1(mm) | D2(mm) |
---|---|---|---|
2# | 280 | 210 | 260 |
2.8# | 290 | 340 | |
3.15# | 325 | 375 | |
3.55# | 320 | 365 | 415 |
4# | 370 | 410 | 460 |
4.5# | 460 | 510 | |
5# | 510 | 550 | |
5.6# | 450 | 570 | 620 |
6.3# | 640 | 690 | |
7.1# | 720 | 770 | |
8# | 630 | 810 | 860 |
9# | 910 | 960 | |
10# | 1010 | 1060 | |
11.2# | 1130 | 1180 |
Gildandi gildissvið
1. Það á við um staðina í Zone 1 og Zone 2 af sprengiefni gas umhverfi;
2. Það á við um staðina í Zone 21 og 22 af brennanlegt ryk umhverfi;
3. Hentar fyrir IIA, IIB og IIC umhverfi fyrir sprengiefni;
4. Applicable to T1-T4 hitastig group;
5. It is widely used in oil refining, chemical, textíl, gas station and other dangerous environments, olíupallar á hafi úti, olíuflutningaskip og fleiri staði;
6. Indoor and outdoor.