23 Year Industrial Explosion-Proof Manufacturer

+86-15957194752 aurorachen@shenhai-ex.com

ExplosionProofAirConditioningBKFR|ProductCenter

Explosion Proof Electrical Apparatus/

Explosion Proof Air Conditioning BKFR

Type:Explosion Proof Air Conditioning

Color:Grey

Ex Mark:Ex db eb ib mbIIB T4 Gb,Ex db eb ib mbIIC T4 Gb

IP Rating:IP66

Model Number:BKFR

Warranty(Year):3-Year

Place of Origin:Zhejiang, China

Product Weight(kg):50

  • Product Details
  • About Us
  • FAQ
  • Packing & Delivery

Technical Parameter

explosion proof air conditioning bkfr-9

ModelBKFR-25BKFR-35BKFR-50BKFR-72BKFR-120
Rated voltage/frequency220V/380V/50Hz380V/50Hz
Rated cooling capacity (W)260035005000726012000
Rated heat (W)288039005700810012500
Input power (P number)1P1.5P2P3P5P
Refrigeration input power/current (W/A)742/3.31015/4.61432/6.52200/103850/7.5
Heating input power/current (W/A)798/3.61190/5.41690/7.62600/11.83800/7.5
Applicable area (m ²)10~1213~1622~2727~3450~80
Noise (dB)indoor34.8/38.836.8/40.840/454852
outdoor4950535660
Overall dimension (mm)Indoor unit265x790x170275x845x180298x940x200326x1178x253581x1780x395
Outdoor unit540x848x320596x899x378700x955x396790x980x4401032x1250x412
Control box300x500x190300x500x190300x500x190300x500x190250x380x165
Weight (kg)Indoor unit1210131863
Outdoor unit11415168112
Control box107
Length of connecting pipe4
Explosion proof signEx db eb ib mbIIB T4 Gb Ex db eb ib mbIIC T4 Gb
Maximum outer diameter of incoming cableΦ10~Φ14mmΦ15~Φ23mm

Split explosion-proof air conditioning treatment

1. Wall mounted explosion-proof air conditioners and floor mounted explosion-proof air conditioners are mainly used for explosion-proof treatment of outdoor units and indoor units on the basis of ordinary air conditioners, as follows:

(1) Outdoor unit: it is mainly used for internal electrical control part, compressor, outdoor fan, protection system, heat dissipation system and refrigeration system explosion proof treatment shall be carried out in a unified way. Its overall dimensions are the same as those of the external units of ordinary hanging air conditioners, and its installation method is also the same as that of the external units of ordinary hanging air conditioners.

(2) Indoor unit: it mainly adopts special process treatment methods and manufacturing methods to decompose the internal electrical control part, and then re conduct explosion-proof design, manufacturing and processing to form an independent explosion proof control box, with manual control function, its hanging external dimension is the same as that of the ordinary hanging internal machine, and its installation method is also the same. But the explosion-proof indoor unit is increased a hanging explosion-proof control box is provided, and its dimensions are shown in the figure below.

2. A variety of explosion-proof forms are used outside the explosion-proof indoor unit and outdoor unit, and the intrinsically safe explosion-proof circuit is used for the weak current control part.

Product Features

1. Explosion proof air conditioner is made of explosion-proof treatment on the basis of ordinary air conditioner, with reliable explosion-proof performance and no impact on the performance of the original air conditioner.

2. Explosion proof air conditioners can be divided into: split wall mounted type and floor mounted type according to structure, and can be divided into: single cold type and cold and warm type according to function.

3. The connection of explosion-proof air conditioner pipeline is consistent with that of ordinary air conditioner. The electrical connection must be in accordance with the requirements of explosion-proof electrical installation process. The power supply must be introduced into the explosion-proof control box first, and then divided from the explosion-proof control box.
Do not introduce the indoor unit and outdoor unit.

4. The explosion-proof control box is equipped with a power switch.

5. Steel pipe or cable wiring is acceptable.

explosion proof air conditioning bkfr-10
explosion proof air conditioning bkfr-11
explosion proof air conditioning bkfr-12
explosion proof air conditioning bkfr-13
explosion proof air conditioning bkfr-14
explosion proof air conditioning bkfr-15
explosion proof air conditioning bkfr installation dimensions-1
explosion proof air conditioning bkfr installation dimensions-2

Applicable Scope

1. It is applicable to the places in Zone 1 and Zone 2 of explosive gas environment;

2. Suitable for IIA, IIB and IIC explosive gas environment;

3. Applicable to T1~T6 temperature groups;

4. It is applicable to dangerous environments such as oil exploitation, oil refining, chemical industry, gas station, offshore oil platforms, oil tankers and metal processing;

5. It is used for temperature regulation in workshops, control rooms, laboratories and other fields.

company profile-2 sample room our certificateexhibition

Q: Are you factory or trading company?
A: We are a factory and provide OEM services. Our main products are explosion-proof lightings, explosion-proof distribution box, explosion-proof cable gland, explosion-proof fans, explosion-proof junction box and anti-corrosion & dustproof & waterproof lights.

Q: What certificates do you have?
A: We have passed ATEX, IECEx, and with a lot of National Patents.

Q: What place are your products used in?
A: They are widely used in petroleum chemical, aerospace, coal electrical power, railway, metallurgy, shipbuilding, medicine, marine, wine-making, fire fighting, municipal, gas station and other industries.

Q: Can I have a sample order?
A: Yes, we welcome sample orders to test and check quality. Mixed samples are acceptable.

Q: Can youaccept customized?
A: Yes. Please inform us and confirm the design firstly based on our sample.

packing delivery

Prev:

Next:

Leave a Reply

Get a Quote ?