25 Year Industrial Explosion-Proof Manufacturer
Technical Article
Technical Comparisons

What Is the Temperature When the Explosion-Proof Light Is Working

The maximum temperature rating for T1 is 450 degrees Celsius, while the minimum for T6 is 85 degrees Celsius. Any temperature between T6 (85°C) and T1 (450°C) is permissible.

Gas ClassificationTemperature Group
-T1T2T3T4T5T6
-T>450450≥T>300300≥T>200200≥T>135135≥T>100100≥T>85
IMethane
IIAEthane, Propane, Acetone, Phenethyl, Ene, Aminobenzene, Toluene, Benzene, Ammonia, Carbon Monoxide, Ethyl Acetate, Acetic AcidButane, Ethanol, Propylene, Butanol, Acetic Acid, Butyl Ester, Amyl Acetate Acetic AnhydridePentane, Hexane, Heptane, Decane, Octane, Gasoline, Hydrogen Sulfide, Cyclohexane, Gasoline, Kerosene, Diesel, PetroleumEther, Acetaldehyde, TrimethylamineEthyl Nitrite
IIBPropylene, Acetylene, Cyclopropane, Coke Oven GasEpoxy Z-Alkane, Epoxy Propane, Butadiene, EthyleneDimethyl Ether, Isoprene, Hydrogen SulfideDiethylether, Dibutyl Ether
IICWater Gas, HydrogenAcetyleneCarbon DisulfideEthyl Nitrate
Dana Lin
Dana Lin Senior Compliance & Safety Engineer

Specializes in global explosion-proof standards (ATEX/IECEx) and rigorous technical compliance, providing the foundational engineering data for industrial safety.

Request a Quote
25+ Years Factory
ATEX / IECEx Certified
Global Delivery